The high-temperature self-regulating heat tracing tape uses a semiconductor self-regulating heating core tape and parallel circuits that can be cut on-site. It automatically adjusts output along the heating loop according to ambient temperature and thermal loss of the insulation layer. It is suitable for frost protection and maintaining a process temperature up to 150°C for high-temperature process pipelines, valves, instrument lines, storage tanks, and equipment, and can withstand intermittent high temperatures caused by steam purging.

Rated Voltage
220–240V AC
Rated Output Power (10°C)
10 / 20 / 30 / 39 / 49 / 66 W/m
Maximum Sustained Temperature
150°C
Maximum Continuous Exposure Temperature (Power Off)
204°C

Product highlights

  • The semiconductor heating core tape adjusts output section by section along the loop to compensate for local heat loss changes.
  • The parallel loop structure allows cutting to on-site dimensions within the specified maximum loop length.
  • 10 / 20 / 30 / 39 / 49 / 66 W/m power ratings cover different high-temperature maintenance loads.
  • Fluoropolymer insulation and outer jacket are suitable for high-temperature and corrosive industrial environments.
  • Can be used for process pipelines, valves, instrument lines, and equipment that need to withstand steam purging temperatures.

Technical specifications

Rated Voltage
220–240V AC
Rated Output Power (10°C)
10 / 20 / 30 / 39 / 49 / 66 W/m
Maximum Sustained Temperature
150°C
Maximum Continuous Exposure Temperature (Power Off)
204°C
Maximum Intermittent Exposure Temperature
250°C
Minimum Installation Temperature
-60°C
Heating Structure
Parallel Conductive Bus + Semiconductor Self-Regulating Heating Core
Insulation and Sheath
Fluoropolymer Insulation, Metal Braid, and Fluoropolymer Outer Sheath
Applicable Scenarios
Freeze Protection and Temperature Maintenance for High-Temperature Process Pipelines, Valves, Instrument Lines, Storage Tanks, and Equipment
Operating Capability
Can withstand intermittent high temperatures caused by steam purging
Circuit Design
Determined based on rated voltage, output power, minimum starting temperature, protective switch, and installation conditions
Heat Tracing Products
Back to products
Low-Temperature Self-Regulating Heat Tracing Cable
01

Low-Temperature Self-Regulating Heat Tracing Cable

The low-temperature self-regulating heat tracing cable uses two parallel bus wires and a PTC semiconductor polymer heating core tape. The core tape automatically adjusts output according to local pipe temperature changes: power increases when the temperature drops and decreases when the temperature rises. It is suitable for freeze protection, anti-freezing, and maintaining process temperatures up to 65°C for pipelines, valves, tanks, and equipment in water supply and drainage, fire protection, petrochemical, and other industries.

  • PTC core tape adjusts heating output segment by segment, adapting to different heat dissipation at various pipe positions
  • Parallel busbar structure, can be cut to installation size within the specified maximum loop length
  • self-regulating feature reduces the risk of continuous overheating at overlapping installation positions
Medium-Temperature Self-Regulating Heat Tracing Cable
02

Medium-Temperature Self-Regulating Heat Tracing Cable

The medium-temperature self-regulating heat tracing cable uses parallel bus wires and PTC semiconductor polymer heating core tape, which can automatically adjust the output according to local temperature changes of the pipeline. It is suitable for antifreeze, anti-condensation, and 0–105°C process temperature maintenance of industrial pipelines, valves, storage tanks, and equipment in petroleum, chemical, steel, and power industries.

  • The PTC core tape adjusts the heating output in segments to compensate for heat loss variations at different positions of the pipeline.
  • The parallel loop structure allows cutting according to installation size within the specified maximum loop length.
  • 35 / 45 / 50 / 60 W/m power levels cover medium-temperature antifreeze and process temperature maintenance requirements.
Parallel Constant-Wattage Heat Tracing Cable
03

Parallel Constant-Wattage Heat Tracing Cable

The parallel constant-wattage heat tracing cable uses two parallel insulated copper busbars and periodically connected resistance heating wires to form continuous parallel heating units. After electrification, it maintains a stable output per unit length and is suitable for frost protection, insulation, and process temperature maintenance for industrial pipelines, valves, instruments, storage tanks, and equipment; temperature control and circuit protection must be used during operation.

  • Continuous parallel heating units provide stable output power per unit length
  • Can be cut to integer multiples of the heating section length, with on-site connection to power supply and end accessories